FREIGHT ELEVATOR
KOMS cargo elevator is widely used in shopping malls, docks, stations and other places where goods are concentrated. It performs the duty of cargo transportation. Relying on the support of advanced technology and the perfect car design and manufacturing, Koms cargo elevator has super carrying capacity, is not afraid of the external influence of the bad environment, and always maintains a stable and reliable operation state.
By using advanced microcomputer control technology and technology integration, the performance and quality of the cargo elevator are greatly improved, and the failure rate is greatly reduced; because of the frequency conversion speed regulation, the operation comfort can reach the same perfection as the passenger elevator.
KOMS ELEVATOR 4 ADVANTAGES
1. Energy conservation
VVVF voltage regulation and speed regulation technology, elevator operation power consumption and power supply capacity adopted by the frequency conversion freight elevator will be greatly reduced, nearly 20% energy saving compared with the traditional AC double speed drive, fully achieving good energy saving advantages.
2. Excellent torque characteristics
The biggest characteristic of VVVF speed regulation of variable frequency freight elevator is its constant torque characteristic. Regardless of the heavy load, its running speed, comfort and leveling accuracy are not affected.
3. Excellent speed control performance
VVVF speed control of variable frequency freight elevator can smoothly adjust the speed of the elevator, greatly improving the comfort, leveling accuracy and running noise of the elevator. Deliver the goods to the destination safely and smoothly.
4. Operation blocking 10 second protection function
In case of emergency jamming during the operation of the goods elevator, the computer program is set to stop the operation within 10 seconds.
load | opening type | speed | cabin size | door opening | hoist-way size | Maximum lifting height | Minimum floor spacing | power | Guide rail bracket spacing | ||||||
cw | cd | ch | dw | dh | hw | hd | mins | mink | max r | min d | p | dbgrb | |||
(kg) | (m/s) | (mm) | (mm) | (mm) | (mm) | (mm) | (mm) | (mm) | (mm) | (mm) | (mm) | (mm) | kw | (mm) | |
1000 | Non connectivity | 0.5 | 1350 | 1750 | 2200 | 1300 | 2100 | 2400 | 2400 | 1500 | 4500 | 40000 | 2700 | 3.4 | 2000 |
Breakthrough | |||||||||||||||
2000 | Non connectivity | 1700 | 2600 | 1500 | 2700 | 3200 | 4800 | 6.7 | |||||||
Breakthrough | |||||||||||||||
3000 | Non connectivity | 2000 | 2700 | 1800 | 3100 | 3350 | 4800 | 30000 | 13.9 | ||||||
Breakthrough |